We understand that finding a trusted, certified and local electrician to help can be a difficult task…
Kings Electrical and AC Services is proud to service the entire Broward County, Palm Beach County and even up to the Orange and Seminole Counties area from our centrally located office in Coral Springs FL.
We want to be your trusted local air conditioning & electrician provider!
Scroll to see our Air Conditioning, and Electrician Reviews in Orlando and South Florida.
Check out all our reviews from people in your neighborhood! Just scroll down and find your city!
Don’t see you city listed below scroll the map and see our entire Orlando, Coral Springs and South Florida service area? No problem! We can’t list them all! Call Kings today and get the red carpet treatment wherever you are in our area.
Recent Jobs and Reviews in Coral Springs, FL
Coral Springs, FL at a glance
Kings Electric & Air Conditioning (Coral Springs) has completed 25 jobs in Coral Springs, FL between September 2018 and October 2018.
The most recent job was on October 2, 2018.
Kings Electric & Air Conditioning (Coral Springs) completed its first job in Coral Springs, FL in January 2014.
Our Local Reviews by City
- Altamonte Springs, FL (4)
- Apopka, FL (6)
- Aventura, FL (1)
- Boca Raton, FL (84)
- Boynton Beach, FL (39)
- Casselberry, FL (5)
- Chuluota, FL (2)
- Coconut Creek, FL (14)
- Cooper City, FL (1)
- Coral Springs, FL (110)
- Dania Beach, FL (1)
- Davie, FL (26)
- Deerfield Beach, FL (23)
- Delray Beach, FL (33)
- Doral, FL (1)
- Fort Lauderdale, FL (42)
- Geneva, FL (1)
- Greenacres, FL (7)
- Hallandale Beach, FL (3)
- Highland Beach, FL (1)
- Hollywood, FL (22)
- Homestead, FL (1)
- Hypoluxo, FL (1)
- Kissimmee, FL (2)
- Lake Mary, FL (5)
- Lake Worth, FL (8)
- Lake Worth Beach, FL (1)
- Lantana, FL (1)
- Lauderhill, FL (8)
- Lighthouse Point, FL (8)
- Longwood, FL (13)
- Loxahatchee, FL (1)
- Maitland, FL (3)
- Margate, FL (12)
- Miami, FL (8)
- Miami Gardens, FL (2)
- Miramar, FL (13)
- North Lauderdale, FL (4)
- North Miami Beach, FL (1)
- Oakland Park, FL (1)
- Ocoee, FL (3)
- Orlando, FL (74)
- Oviedo, FL (8)
- Palm Beach, FL (2)
- Palm Beach Gardens, FL (8)
- Palm Springs, FL (1)
- Parkland, FL (28)
- Pembroke Pines, FL (35)
- Plantation, FL (18)
- Pompano Beach, FL (27)
- Royal Palm Beach, FL (1)
- Sanford, FL (2)
- Southwest Ranches, FL (2)
- Sunrise, FL (25)
- Surfside, FL (4)
- Tamarac, FL (46)
- Wellington, FL (2)
- West Palm Beach, FL (12)
- Weston, FL (9)
- Wilton Manors, FL (3)
- Windermere, FL (24)
- Winter Garden, FL (18)
- Winter Park, FL (7)
- Winter Springs, FL (4)
Job Locations and Reviews
1)-----Remove exsitng 80 amp panel that is currently double tapped at meter enclosure. 2)-----Install junction box at exsitng circuits conduit that was connected to sub panel. 3)-----Remove single lugs at meter enclosure and install double lugs. 4)-----Install 100 amp disconnect next to meter enclosure. 5)-----Install new 3 gauge copper feeders between meter and new disconnect. 6)-----Run 1 1/4" PVC conduit from disconnect around house to back patio. (Approximately 100 ft.) 7)-----Install 100 amp 12-24 circuit outdoor panel at back patio. 8)-----Pull 3 gauge copper feeders from disconnect to patio panel. 9)-----Install 50 amp GFI breaker at new panel on patio. 10)-----Run 1 inch PVC conduit from patio panel to hot tub location. 11)-----Run flex into hot tub motor and hook up hot tub. 12)-----Relocate new outlet for water softener into outdoor main breaker panel.
1)-----Assemble and install 2 customer supplied fans.
Main breaker is off Turn on and check everything Make sure they are working
Install customer supplied motion light
Install new 4 prong outlet
Diagnose intermittent power at ac wall unit
1)-----Install customer supplied emergency light.
Replace (2) emergency ballasts
Replace (1) 6 lamps fluorescent fixture Replace (1) 6 lamps fluorescent fixture
1)-----Remove all wiring and junction boxes from half wall. 2)-----Cut conduit that has all circuits main feeds down to desired location of outlet to be installed. 3)-----Install deep junction box in wall at main feed conduit. 4)-----Extend circuit from main feed junction box to exisitng outlet junction box on opposite side of wall. 5)-----Install outlet and cover plate at both junction boxes. 6)-----Trace out both fan switches and reconfigire wiring so that they operate on 1 switch line. (Preferably 1 switch, but might have to be 2 switches on a 3 way system)
1)-----Remove bathroom vanity light fixture. 2)-----Cut off bad wire to exisitng switch line of bathroom light fixture junction box and pull slack of exisitng good wire back into junction. 3)-----Pull slack of 3 other lines to other side of stud and cut bad wire off those 3 lines. 4)-----Install junction box in wall and reconnect all lines. 5)-----Extend feed to bathroom light junction box from newly installed junction box. 6)-----Reinstall bathroom light fixture.
Replace (2) GFI outlets
1)-----Schedule disconnect with FPL. 2)-----Remove 200 amp meter enclosure. 3)-----Install new 200 amp meter enclosure. 4)-----Remove 200 amp main lug outdoor circuit panel. 5)-----Install new 200 amp main breaker 20/40 circuit outdoor panel. 6)-----Label panel. 7)------Install new 2/0 gauge copper feeders between meter and main panel. 8)-----Remove aluminum feeders between main outdoor panel and indoor circuit panel. 9)-----Install new #2 gauge copper feeder wires between main outdoor panel and indoor circuit panel. (Approximately 3*70 ft.) 10)-----UPDATE GROUNDING INCLUDES: install 2 new ground rods, 1 water pipe ground and 1 low voltage ground bridge all interconnected with #4 gauge bare copper wire. 11)-----Pull permit and get inspection.
1.....replace old surge protector 2.....install one new dbl pole breaker for new surge protector to correct double tapping.
Replace (1) capacitor and (1) contactor Add 3-6 lbs R22
1)-----Reinstall customer supplied generator transfer panel. 2)-----Pull exisitng wires of circuits connected to transfer panel through exisitng conduit to house panel. 3)-----Reconnect all circuits to house panel as labeled. 4)-----Reinstall generator outlet. 5)-----Supply and install 100 amp breaker in house panel and connect power supply wires from transfer panel to house panel.
Replace bathroom gfi outlet
Wire up (4) cubicle wiring 1 year warranty
Troubleshoot no power
Replace breaker
Install customer supplied 350lb chandelier
1)-----Remove burnt 100 amp main breaker and meter socket. 2)-----Supply and install new 100 amp main breaker and meter socket. NOTE: Meter socket is special order.
Diagnostic on outside outlet
Remove circuit out of panel
Supply and install new 20amp 2p breaker for sprinkler in order to avoid double tapping